Observability export
Phase 22 provides finite snapshots through ping, check and doctor:
| Format | Output | Delivery |
|---|---|---|
prometheus |
Prometheus text 0.0.4 gauges | Atomic textfile publication to an existing exporter |
logs |
One reduced JSON object per line | Existing log collector reads stdout or a file |
otlp |
OTLP/HTTP JSON ExportLogsServiceRequest |
POST with application/json to a collector's /v1/logs |
webhook |
JSON envelope with export_version: v1 and records |
Explicit HTTPS POST to a compatible receiver |
agenthealth check examples/core-check/agenthealth.yaml --format prometheus
agenthealth check examples/graph-check/agenthealth.yaml --format logs
agenthealth check examples/core-check/agenthealth.yaml --format otlp
agenthealth check examples/core-check/agenthealth.yaml --format webhook
Health exit codes remain 0–5; invalid configuration, invalid output and write failure use 6. A nonzero health code still produces a valid snapshot. SDKs continue to use canonical JSON. Exports are reduced projections, not replacements for the AHS result schema. See the delivery example.
Evidence and privacy
Each record has kind (node, check or edge), node, target type and
status. Check records add dimension; node records include latency_ms when
measured. Edge records add a unique snapshot-local edge, parent, configured
relationship and effective critical (default true). Empty relationship means
unspecified. Node health is not replaced by its contribution to a parent.
All six statuses remain distinct. Transport steps and diagnostic codes are
omitted along with arbitrary messages.
Explicit graph IDs deduplicate node/check evidence. Every incoming edge retains
its own policy; a shared node's outgoing edges export once. Nodes without IDs
remain distinct. The exporter expects coherent engine-generated snapshots;
it does not reconcile conflicting caller-supplied results with the same ID.
Aliases (node-1, edge-1) are assigned in configuration traversal order and
reset for every snapshot. Do not correlate them across reordered configurations.
Direct and composite agents both retain type agent; downstream/path relationships
carry the available distinction. No role is inferred from names.
Configured names, IDs, URLs, credentials and diagnostic text are excluded. Topology shape, counts, target types, relationships, status and timing remain visible: this is data minimization, not topology anonymization or tenant isolation. Restrict collector/file access accordingly. No original identifier opt-in exists.
Metric mapping
agenthealth_status is a one-hot gauge for each of the six status values.
Other labels are kind, node, parent, type, dimension, relationship,
critical and edge; inapplicable labels are empty strings. Edge labels prevent
repeated relationships from producing duplicate series. agenthealth_latency_seconds
converts measured node latency from milliseconds, with node and type labels.
Missing latency produces no sample. No counter, histogram or fabricated zero
latency is emitted. Cardinality grows with configured nodes, checks and edges;
use bounded configurations and replace the whole textfile on every run.
OTLP emits logs with scope agenthealth, a shared observedTimeUnixNano, and
JSON-encoded reduced records in body.stringValue. It does not fabricate trace
IDs, spans, resource identity, or severity mapping. The timestamp records export
time, not the start of each check. Webhook records use the same evidence mapping.
The formats follow the Prometheus exposition specification and OTLP JSON specification. Collector ingestion and hosted-provider compatibility require separate measured interoperability evidence. This baseline has no scrape server, remote-write, gRPC exporter, durable queue, authentication manager, automatic delivery or retry. AHP endpoints, health schemas and Kubernetes probes are unchanged.
Phase 24 conformance evidence
Redaction, status mapping, one-hot gauges and duplicate-edge uniqueness are included in the reference catalog. The offline command does not accept exports or establish collector delivery. See the conformance guide and cross-phase review.